Multi-Family Bond Program Energy and
Weatherization Requirements
These requirements are for new
construction projects only. For acquisition and rehab projects,
contact nhd@nvhousing.state.nv.us
1. All units will have appliances that are 'Energy Star' rated;
2. All living units will have reversible ceiling fans;
3. All living units will have thermostats that have
programmable double set back features with instructions available to
tenants.
4. All laundry facilities will have appliances that are 'Energy
Star' rated;
5. Ceiling insulation in all living units will have an
"R-value" of not less than:
| Northern Nevada |
38 |
| Southern Nevada |
30 |
| Lake Tahoe |
38 |
| Rural Nevada |
38 |
6. Wall insulation in all living units will have an
"R-value" of not less than:
| Northern Nevada |
19 |
| Southern Nevada |
11 |
| Lake Tahoe |
21 |
| Rural Nevada |
19 |
7. All living units will have
heated furnaces rated at least 90% AFUE;
8. All living units will have water heating
devices that are:
| Items |
GAS type |
ELECTRIC type |
| For 30 gallons |
.58 Energy Factor |
.89 Energy Factor |
| For 40 gallons |
.56 Energy Factor |
.88 Energy Factor |
| For 50 gallons |
.55 Energy Factor |
.86 Energy Factor |
9. All units will have double paned 'low
e' windows;
10. All eastern and western exposure windows will have 'solar screens' on
projects in Southern Nevada.
11. Air conditioning requirements:
Zone
Minimum SEER
Rating
Tonnage Requirement
Southern
Nevada
12 or greater
SEER
Variable by room size
Northern
Nevada
10 or greater
SEER
Variable by room size
If a developer chooses to
use a heat pump mechanism, the cooling
component must meet the above criteria
for air conditioning and heating.
|